{"product_id":"fluke-5520a-multi-product-calibrator","title":"Fluke 5520A Multi-Product Calibrator","description":"\u003ch2 data-start=\"589\" data-end=\"633\"\u003e\u003cstrong data-start=\"592\" data-end=\"631\"\u003eProduct Description \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"634\" data-end=\"1051\"\u003eThe \u003cstrong data-start=\"638\" data-end=\"678\"\u003eFluke 5520A Multi-Product Calibrator\u003c\/strong\u003e is a high-accuracy, laboratory-grade calibration system designed to support a wide range of electrical calibration applications. Trusted by calibration laboratories, metrology centers, and industrial maintenance facilities, the 5520A provides precise sourcing and measurement for \u003cstrong data-start=\"959\" data-end=\"1050\"\u003eDC and AC voltage, current, resistance, capacitance, frequency, thermocouples, and RTDs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1053\" data-end=\"1384\"\u003eEngineered for long-term stability and low uncertainty, the Fluke 5520A enables efficient calibration of digital multimeters, clamp meters, oscilloscopes, power meters, and process instruments. Its robust architecture and automated calibration support help reduce downtime while maintaining traceability to international standards.\u003c\/p\u003e\n\u003cp data-start=\"1386\" data-end=\"1585\"\u003eWith Fluke’s renowned reliability and precision, the 5520A serves as a cornerstone instrument for professional calibration environments requiring \u003cstrong data-start=\"1532\" data-end=\"1584\"\u003eaccuracy, versatility, and confidence in results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"1592\" data-end=\"1613\"\u003e\u003cstrong data-start=\"1595\" data-end=\"1611\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1616\" data-end=\"1672\"\u003eMulti-product electrical calibrator for laboratory use\u003c\/p\u003e\n\u003cp data-start=\"1675\" data-end=\"1744\"\u003eCalibrates voltage, current, resistance, capacitance, and frequency\u003c\/p\u003e\n\u003cp data-start=\"1747\" data-end=\"1801\"\u003eSupports thermocouple and RTD temperature simulation\u003c\/p\u003e\n\u003cp data-start=\"1804\" data-end=\"1855\"\u003eHigh accuracy and long-term measurement stability\u003c\/p\u003e\n\u003cp data-start=\"1858\" data-end=\"1913\"\u003eIdeal for calibration labs and metrology applications\u003c\/p\u003e\n\u003cp data-start=\"1916\" data-end=\"1971\"\u003eAutomates calibration workflows to improve efficiency\u003c\/p\u003e\n\u003cp data-start=\"1974\" data-end=\"2024\"\u003eCompatible with a wide range of test instruments\u003c\/p\u003e\n\u003cp data-start=\"2027\" data-end=\"2071\"\u003eReliable bench-top laboratory construction\u003c\/p\u003e\n\u003cp data-start=\"2074\" data-end=\"2120\"\u003eDesigned for traceable calibration standards\u003c\/p\u003e\n\u003cp data-start=\"2123\" data-end=\"2164\"\u003eTrusted Fluke precision and performance\u003c\/p\u003e\n\u003ch2 data-start=\"2171\" data-end=\"2198\"\u003e\u003cstrong data-start=\"2174\" data-end=\"2198\"\u003eSpecifications Table\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2200\" data-end=\"2715\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2200\" data-end=\"2235\"\u003e\n\u003ctr data-start=\"2200\" data-end=\"2235\"\u003e\n\u003cth data-start=\"2200\" data-end=\"2220\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2219\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2220\" data-end=\"2235\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2222\" data-end=\"2233\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2271\" data-end=\"2715\"\u003e\n\u003ctr data-start=\"2271\" data-end=\"2294\"\u003e\n\u003ctd data-start=\"2271\" data-end=\"2279\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2279\" data-end=\"2294\" data-col-size=\"md\"\u003eFluke 5520A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2295\" data-end=\"2341\"\u003e\n\u003ctd data-start=\"2295\" data-end=\"2313\" data-col-size=\"sm\"\u003eInstrument Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2313\" data-end=\"2341\"\u003eMulti-Product Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2342\" data-end=\"2422\"\u003e\n\u003ctd data-start=\"2342\" data-end=\"2366\" data-col-size=\"sm\"\u003eCalibration Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2366\" data-end=\"2422\"\u003eVoltage, Current, Resistance, Capacitance, Frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2423\" data-end=\"2468\"\u003e\n\u003ctd data-start=\"2423\" data-end=\"2445\" data-col-size=\"sm\"\u003eTemperature Support\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2445\" data-end=\"2468\"\u003eThermocouples, RTDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2469\" data-end=\"2521\"\u003e\n\u003ctd data-start=\"2469\" data-end=\"2486\" data-col-size=\"sm\"\u003eAccuracy Level\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2486\" data-end=\"2521\"\u003eHigh-precision laboratory grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2522\" data-end=\"2563\"\u003e\n\u003ctd data-start=\"2522\" data-end=\"2536\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2536\" data-end=\"2563\"\u003eCalibration \u0026amp; Metrology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2564\" data-end=\"2591\"\u003e\n\u003ctd data-start=\"2564\" data-end=\"2578\" data-col-size=\"sm\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2578\" data-end=\"2591\"\u003eBench-top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2592\" data-end=\"2637\"\u003e\n\u003ctd data-start=\"2592\" data-end=\"2604\" data-col-size=\"sm\"\u003eStability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2604\" data-end=\"2637\"\u003eLong-term reference stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2638\" data-end=\"2690\"\u003e\n\u003ctd data-start=\"2638\" data-end=\"2654\" data-col-size=\"sm\"\u003eTypical Users\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2654\" data-end=\"2690\"\u003eCalibration labs, standards labs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2691\" data-end=\"2715\"\u003e\n\u003ctd data-start=\"2691\" data-end=\"2706\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2706\" data-end=\"2715\"\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"2722\" data-end=\"2753\"\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2754\" data-end=\"3076\"\u003eThe Fluke 5520A multi-product calibrator delivers precise, traceable electrical calibration across voltage, current, resistance, frequency, and temperature simulation. Designed for professional calibration laboratories, it provides stable, high-accuracy performance for maintaining compliance with international standards.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":47187265061099,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0794\/4473\/8283\/files\/Fluke_5520A_Multi-Product_Calibrator.png?v=1765810265","url":"https:\/\/oventosystems.com\/products\/fluke-5520a-multi-product-calibrator","provider":"Ovento Systems","version":"1.0","type":"link"}