Megger S1-1568 15 kV Diagnostic Insulation Tester
Insulation & Installation Testers
$8495from
Category
Megohmmeters, multifunction installation testers, earth ground testers and PAT testers.
Insulation & Installation Testers
$8495from
Insulation & Installation Testers
$6495from
Insulation & Installation Testers
$5995from
Insulation & Installation Testers
$4495from
Insulation & Installation Testers
$3495from
Insulation & Installation Testers
$3295from
Insulation & Installation Testers
$2495from
Insulation & Installation Testers
$2295from
Insulation & Installation Testers
$1895from
Insulation & Installation Testers
$1895from
Insulation & Installation Testers
$1795from
Insulation & Installation Testers
$1595from
Insulation & Installation Testers
$1395from
Insulation & Installation Testers
$1295from
Insulation & Installation Testers
$1295from
Insulation & Installation Testers
$1195from
Insulation & Installation Testers
$1095from
Insulation & Installation Testers
$1095from
Insulation & Installation Testers
$995from
Insulation & Installation Testers
$895from
Insulation & Installation Testers
$795from
Insulation & Installation Testers
$749from
Insulation & Installation Testers
$749from
Insulation & Installation Testers
$749from
Insulation & Installation Testers
$649from
Insulation & Installation Testers
$595from
Insulation & Installation Testers
$549from
Insulation & Installation Testers
$549from
This category covers everything from 1 kV installation testers used daily by electrical contractors through to 15 kV diagnostic megohmmeters for generators and transmission cable.
The convention is roughly twice rated voltage plus 1000 V. General installation work up to 1000 V is fully covered by a 1 kV instrument; medium-voltage cable, large motors and generators need 5 kV or above.
Applying 5 kV to equipment rated for 400 V does not produce a better test — it risks damaging insulation that was healthy.
Maximum voltage says nothing about whether the instrument can hold that voltage into a real capacitive load. Instruments intended for large plant specify several milliamps of test current for this reason.
Diagnostic modes matter for rotating machines: polarisation index, dielectric absorption ratio, dielectric discharge and step voltage all reveal deterioration that a single resistance reading misses.
The ratio of the ten-minute insulation reading to the one-minute reading. It indicates moisture and contamination and is largely temperature-independent, which makes it more useful than a single value.
Where included it is stated in the listing. Lead sets are rated to the instrument's output voltage and are a real cost when missing — we can quote replacements.
No. Installation testers add loop impedance, RCD and continuity testing to IEC 61557 for fixed wiring verification. A dedicated insulation tester goes to higher voltages.
Prices shown are indicative for a single tested unit. Quantity pricing, dealer terms and blanket orders are quoted individually. Send the list and we will respond within one business day.